Zuhause> Blog> Characteristics and application of fiber optic pipetting probe

Characteristics and application of fiber optic pipetting probe

July 27, 2023
Characteristics and application of fiber optic pipetting probe
DipTipTM is a small transmission/absorbance probe for microliter spectrophotometers and is the world's smallest fiber optic pipetting probe for UV and visible spectrophotometers.
The tip of the DipTip is only 1.5 mm in diameter, which is equivalent to the size of a 17G needle. It is not only 4-5 times smaller in diameter than other products on the market, but also has a price that is nearly 50% lower. The probe can be applied to all centrifuge tubes on the market and is very useful for measuring protein and DNA samples. This small pipetting probe can also be used for solution dilution. WPI designed this product along with WPI's fiber optic-based spectrophotometer or spectrometer module (TIDAS I) or CCD and light source for analysis of microliter samples.
An example of the use of DipTip is the use of TIDAS II to analyze calf serum (BSA) dissolved in phosphate buffer. The absorbance range and calibration curve are shown in the figure below. A 50-60 microliter sample was taken from a 0.1 ml centrifuge tube to measure its absorbance.


Diptip parameters
Diptip parameters
DIP-UV
DIP-NIR
DIP-UV-SR
Tip diameter
1.5 mm
1.5 mm
1.5 mm
Light path length
2, 5, 10mm
2, 5, 10mm
2, 5, 10mm
Wavelength range (nm)
230-1000
350-1000
200-1000
Required sample volume
20-50 μL
20-50 μL
20-50 μL
Tip immersion depth
7 mm
7 mm
7 mm
Total length ( with handle )
18 cm
18 cm
18 cm
Fiber length ( from connector to tip )
1.5 m
1.5 m
1.5 m
Fiber optic connector
SMA 905
SMA 905
SMA 905
Launch fiber (2) NA = 0.22
400 μm
400 μm
400 μm
Return fiber (1) NA = 0.22
400 μm
400 μm
400 μm
TIDAS I is WPI's high-end spectrometer module based on fiber sampling technology that uses a suitable source and sample cell to perform spectral detection at 195-730 nm at very low noise levels (0.8 milliabsorbance). TIDAS I outperforms conventional spectrophotometers and CCD-based spectrometers with high-precision fiber sampling.
Kontaktiere uns

Author:

Mr. Tom Chen

Phone/WhatsApp:

+8613662258732

beliebte Produkte
Branchen-Nachricheten
unser Kunde

October 14, 2022

You may also like
Related Categories

Mail an Lieferanten

Fach:
E-Mail-Adresse:
Nachrichten:

Your message must be betwwen 20-8000 characters

Kontaktiere uns

Author:

Mr. Tom Chen

Phone/WhatsApp:

+8613662258732

beliebte Produkte
Branchen-Nachricheten
unser Kunde

October 14, 2022

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

senden